(773) 867-0380 Contact Us

Vision Screeners

Functional Vision Analyzer (FVA)

(Upgraded Optec 6500)

Ideal for use in pre- and post-op cataract and refractive surgery and clinical trials

  • Will perform all of the tests needed to evaluate functional vision and more: visual acuity, contrast sensitivity, depth perception, color vision, and potential acuity.
  • Includes F.A.C.T. (contrast sensitivity) tests (sine-wave gratings)
  • 4 lighting conditions – Day and night, with and without glare
  • Meets the FDA clinical research standards
  • Meets ANSI standards with unsurpassed homogeneous illumination
  • EyeView software provides the ability to demonstrate patients’ functional vision with real-world images.
Analysis using the EyeView software.

Request Pricing

Vision Analyzer
Optec FVA Functional Vision Analyzer (Contrast Sensitivity and Glare)

Cleaning

Clean and disinfect the forehead activator and surrounding area gently with disinfectant wipes or a soft, slightly damp, and lint-free cloth with 70% isopropyl alcohol. Clean gently and never spray alcohol directly on the screener surfaces.

FEATURES INCLUDE:

  • New unsurpassed homogeneous illumination
  • Background luminance complies with international standards
  • All light levels microprocessor controlled and continually calibrated
  • Binocular glare testing
  • Target illumination comes standard with 3.0 cd/m2 for night testing, and 85 cd/m2 for day testing, or may be customized* to specific needs with a value range of 1.0 cd/m2 to 125 cd/m2
  • Glare luminance at distance comes standard with 1 Lux and 28 Lux for night glare testing; 10 Lux and 135 Lux for day glare testing
  • Sine Wave Gratings 5 spatial frequencies 1.5, 3, 6, 12, and 18 cycles per degree
  • Potential acuity for a quick assessment of macular function
  • Includes (F.A.C.T.®) contrast sensitivity slide package to evaluate patients’ overall functional vision

* Note: Customized target illumination, glare levels, & test packages must be determined upon order placement.

Click to view full image:

FVA and FACT Slides leaflet

thumbnail of Stereo Optical Product Catalog 09 2024 (reduced)

Stereo Optical Product Catalog

thumbnail of 56181-FACTappendix_FULL-11-2019

F.A.C.T. Appendix

thumbnail of Contrast Sensitivity Function White Paper 05-2022

Contrast Sensitivity Function White Paper

thumbnail of Contrast-Sensitivity-J-of-Cataract-and-Refractive-Surgery-2007

Reprint  – Testing and Reporting Contrast Sensitivity

thumbnail of Contrast-Sensitivity-Testing-Opthalmology-Management-2007

Reprint – Contrast Sensitivity Testing

thumbnail of Repeatability of Contrast Sensitivity Testing in Patients w AMD, Glaucoma, or Cataract 2016

Repeatability of Contrast Sensitivity Testing

thumbnail of Eppig et al, Acta Ophthalmologica 2015 – IOLs and OPTEC 6500

Contrast Sensitivity with Different IOLs

thumbnail of 56180 FVA-CS Sample

Contrast Sensitivity Sample

thumbnail of 56184 FVA MANUAL 05 2019

Functional Vision Analyzer

thumbnail of 56181-FACTappendix_FULL-11-2019

F.A.C.T. Appendix

thumbnail of 32241_MANUAL INSTRUCTION 6500

Optec 6500

thumbnail of Optec Peripheral Test Instructions 05 2019

Peripheral Testing

thumbnail of PN 56183 FACT Slide Instr Manual 07.2017

F.A.C.T. Contrast Sensitivity Slide Instructions

thumbnail of FVA-Record-Form-2017

FVA Record Form

thumbnail of FACT 4 Graphs Record Form

F.A.C.T. Graphs Only

thumbnail of Cataract Functional Disability Test form 11-2023 (fillable)

Cataract Functional Disability Form (Fillable)

 

Learn about the EyeView analysis software, complimentary with the purchase of a new unit of Functional Vision Analyzer (FVA).
Contact us to purchase a downloadable copy at $500 for your existing FVA.

How do I clean and disinfect the screener cover?

Clean and disinfect the forehead activator bar and surrounding area gently with disinfectant wipes or a soft, slightly damp, and lint-free cloth with alcohol. We have used 70% isopropyl alcohol to clean and disinfect our equipment surfaces. Clean gently with a damp cloth and never spray alcohol directly on the screener surfaces.


What is contrast sensitivity?

Contrast sensitivity (CS) refers to the ability of the visual system to distinguish between an object and its background. For example, imagine a black cat on a white snowy background (high contrast) versus a white cat on a white snowy background (low contrast). In all conditions where visual acuity is reduced, CS is reduced as well. However, sometimes CS is reduced more than expected based upon the visual acuity alone. This means that if only visual acuity is tested, the visual disability of the person with relatively reduced contrast sensitivity will be underestimated.


How is CS tested?

CS is tested in two ways: low contrast letters or sine-wave grating with varying spatial frequency. CS testing measures visual performance over a wide range of sizes and contrasts. The purpose of the test is to assess how well a person functions visually to see everyday objects such as faces and signs.


What are the indications for CS testing?

CS testing is useful as an auxiliary means of assessing visual difficulties in patients who test well with a traditional Snellen chart. A Snellen chart employs high contrast, i.e., black letters on a white background. Many people can read the 20/20 line and still complain of visual difficulties, such as driving at night (i.e., low contrast conditions). This may be due to optical aberrations of the visual system, contact lens problems, ocular pathology, complications related to medications, and ocular manifestations of systemic diseases.


Why am I not getting ‘light’ to my vision screener? I have checked that the machine is receiving power.

At least one or both of the left- and right-eye buttons must be illuminated on the control panel for the screener to receive light. If neither button is illuminated, we do not know which eye(s) you want to test. Then there is no light when you look inside the screener and you may think the machine is not on.


Why are some of my slides up side down?

Test slides will appear upside-down or reversed when looking at a near point slide at a far point setting (and vise versa).


What lighting condition is acceptable for the testing room?

Any lighting condition is acceptable for day testing.  Night testing should be administered in a dimly lit room.


Which slide/test responses can be entered into the EyeView software program?

The EDTRS and the contrast sensitivity test slide responses can be entered into the EyeView software program.


How do you change the light bulbs in the vision tester?

There are no light bulbs in the vision tester.  The unit is run solely on LED’s (Light Emitting Diodes).


Why are there two glare levels?

The first glare level is ideal for ‘in practice’ use.  The second glare level is a debilitating glare level (very bright); more useful in clinical studies.


Why won’t my dial/knob advance/reverse?

Most often, the drum will not advance/reverse if the back/rear door is not securely closed.


Can I use glare in any of the lighting conditions (i.e., Day at Near)?

No, glare testing can not be done at the near setting.  However, an alternative will be to use a near lens (in the ancillary holder).


Can glare be used on any other tests besides contrast sensitivity?

Yes, glare can be used on any test, although this is not common.

Functional Vision Analyzer for Contrast Sensitivity

EyeView Software

How to Fix an Upside Down Slide

How to Change a Slide

Vision Screeners

I run a busy practice with 9 doctors and 40 assistants in Corpus Christi, TX. I rely upon my Stereo Optical FVA to provide quick and efficient screening. I own 4 of these units.

Jack McIntyre, ODCorpus Christi, TX

Vision Screeners

I rely on my Functional Vision Analyzer (FVA) in both Research and Clinical Practice, especially for patients with cataracts and/or AMD. The Stereo Optical FVA provides consistent real-life visual simulation of how an individual patient with chronic eye disease actually sees, at distance and near, in terms of contrast and glare, well beyond common 1862 Snellen visual acuity tests.

Stuart Richer, OD, PhD, FAAONorth Chicago, IL

Vision Screeners

The Stereo Optical Functional Vision Analyzer® (FVA) is the gold standard clinical and research instrument for evaluating the quality of vision beyond simple visual acuity.  The FVA reliably measures the contrast sensitivity function with and without disability glare.  This unique instrument therefore provides a full measure of vision assessment, analogous to a full audiogram for hearing function. In addition, the FVA been validated by a number of published clinical papers, and remains the standard in both the eye clinic and pharmacology research laboratory for FDA compliant drug studies. At the Captain James A Lovell Federal Health Care Center, we have used this instrument in several published randomized placebo controlled clinical trials.

Stuart Richer, OD, PhD, FAAONorth Chicago, IL
  • Headrest Tissues – Optec 5000, 2000 & 1000 Series (5000/pkg)

    Code: 2000207

    $76.00
  • Carrying Case – Wheeled for Optec 5000 Series

    Code: 32272

    $540.00
Top